I dont know why they have to lie about it. At $5/8ft board you’d think I paid for the full 1.5. Edit: I mixed up nominal with actual.
I dont know why they have to lie about it. At $5/8ft board you’d think I paid for the full 1.5. Edit: I mixed up nominal with actual.
Um, wait. I would think that violates some sort of law (but I guess maybe we haven’t codified this?). I mean, building plans expect standards in materials, right? So how can a building meet codes if the materials are not within the expected specs?
The 2x4s that have been sized this way do meet structural code. It was found that a full 2x4 is way over spec’d for what they were used for, so why bother wasting extra parts of the tree?
Pretty much everything built with dimensional lumber in the last century has been done with undersized 2x4s, and it’s fine. The name stuck for historical reasons. Companies that build houses and order this stuff by the pallet all know what the real size is, and so do building inspectors.
It’s fine, folks. Nothing to see here.
I’m going to guess they can get away with this because 2x2s aren’t intended for structural use. I’ve never built one into a floor, wall or ceiling.
Used for furring strips everywhere. Line a block wall with them and sheet it for example.
Would you call that a “structural use?”
Structural use means load bearing. So no.
Furring strips are used in plenty of places, I provide one example where it is used in most residential homes to support drywall.
Is it not structural if it’s holding ceiling drywall…? So why are people still bickering that walls aren’t structural when they still hold drywall up…?
If it’s part of a code wall detail, would that not be structural…?
What’s with the pedantism over something like this to try and save face over not knowing what a furring strip is?
No, that’s is not structural.
Structural means it’s intended to support and transfer loads in a way that cannot be safely removed.
Since neither the furring strips or drywall are part of a structural requirement, they are not load bearing.
Drywall is structural, when used on block walls it helps provide lateral support.
This is why being pedantic usually backfires.
Drywall is inherently structural.
Regardless. It’s furring strips, you want to argue furring strips aren’t used in structural applications? They are used in all three applications the person said they haven’t used them in. They also claimed to be a wood wroker elsewhere, so I don’t see how they would use anything structural anyways….
No shit. You’re giving us a master class on it right now.